c\temp-USB-80C Single-Use Coin Cell
This is our single-use dry ice temperature data logger with USB connectivity. Meets new IATA regulations for labelling.
Memory: 8k
Temperature Range: -80°C to +30°C / -113°F to +86°F
Description
Our new compact c\temp-USB -80C single-use dry ice data logger now comes with USB built-in so that downloading data is fast and easy! Connect to your computer and obtain real-time and or stored -80°C readings immediately.
Our time-tested dry ice logger, used by Fortune 500 Companies globally for dry ice shipments, NOW comes with USB connectivity. Now connect immediately to your PC with this new USB enhancement without having to worry about bringing the data logger to room temperatures. You asked and we delivered! This new product is IP66 rated for moisture prevention commonly associated with dry ice shipments. Designed for measuring temperatures during the transportation of biologics, vaccines, chemicals, pharmaceuticals and ultra frozen products, this new product will surely satisfy your critical dry ice shipments.
Functions: The internal firmware provides the following features: start time, intervals, end description for special instructions, alarm values,recording status, measurement data, firmware version, serial and tracking number, and model type. Pre-programmed features also include language conversion on the fly from English to Spanish, Portuguese, Japanese, French and German. To start the recorder, simply press the start button!
Computer Ready: After or during recording, simply download all of its data to your PC with a mini USB cable and Marathon’s easy-to-use MDAS software. Compatible with Microsoft Windows XP, Vista and 7, 8 & 10. 21CFR compliant software is available with full database capabilities. Software and cables are sold separately.
Note: a minimum order consists of 20 units.
Marathon will pay a US $3 rebate for each used electronic data logger (ctemp red, gray, yellow or blue) returned to us. This will help us meet our green environmental objectives and our customers will save the cost of the disposal of the electronic waste, which contains printed circuit boards and alkaline or lithium batteries. Go to the REBATE page for more information and to download the return form.
c\temp-USB-80C – SKU #7044 | |
---|---|
Logger Category, Description | Category 2, Single-Use. Dry ice temperature compact data logger with Mini-USB connection to PC and internal thermistor. |
Memory/Storage | 8k memory (approximately 8,000 measurements) |
Internal Sensor | Precision NTC Thermistor Range: -80°C to +30°C / -113°F to +86°F Accuracy: ±0.5°C at 0° to 10°C, ±2.0°C at extremes / ±0.9°F at 32° to 50°F, ±3.6°F at extremes |
External Sensor/Probe count and connector type | None |
Alarm Programming | Pre-programmed to your specifications. Also user configurable at any time before the logger has been started. High and low alarm limits can be set by temperature and time. |
Alarm Modes | Exceed Limit, Continuous Interval, Cumulative. See Alarms page for more information. |
Alarm Reset Options | None |
Alarm Notifications | Red LED flashes when alarm has been triggered. See Alarms page for more information. |
Audible Alarm | None |
Display | None |
Indicators | LED indicators: on/recording (green), alarm (red) |
Size and Weight | 9.0 cm(l) x 5.0 cm(w) x 2.8 cm (h) / 3.0 in.(l) x 1.96 in (w) x 1.1 in.(h) 85 grams / 3.0 oz. |
CE Certified | Yes |
Water-resistant | Yes, IP66 rated |
Internal Firmware, Internal Clock Accuracy | Internal Clock, Start/Stop time, Interval, User description, Alarm values, Recording status, Firmware version, Serial number, Model. Clock Accuracy is better than 2 minutes per month on average at normal temperatures (-29°C to +72°C). For loggers directly exposed to temperatures at or below -80°C, the expected accuracy is °15 minutes per month |
Measurement Intervals | Programmable from 2 seconds per reading. See Duration Chart for examples. |
Computer Interface (physical) | Mini-USB |
Data Retrieval Method | Download to PC using a compatible cable and software |
Programming (Initialization) Method | Comes pre-programmed to your specifications. Also user programmable through PC using a compatible cable and Marathon software before the unit has been started. |
Wireless Connection and Range | None |
Remote Monitoring and Network Connection type | None |
Required Accessories: | Compatible Software (1 required for operation): • MDAS Read-Only • MDAS-Pro, • 21 CFR Computer Interface (1 required for operation): • USB to Mini-USB cable |
Optional Accessories: | None |
Included paperwork | Quality Control sheet, NIST certificate, Packing List included with all purchases. See the Calibration page for more information. |
Optional Paperwork | Calibration Report including data included with purchase of Optional Calibration. See the Calibration page for more information. |
Power Source, Battery Life and Replacement | coin cell CR2450 – single 3.6 V lithium with 1 year operating life and 3 year shelf life. 0.13 g of lithium Dia 3.2cm Height 0.65 CM IATA approved battery – No labeling required. See Battery Performance page for more information. Batteries are changed as part of the recommended annual recalibration. For battery replacement only, Call for price. |
Warranty | 1 Year Limited Warranty |
Specifications subject to change without prior notice.
Centralized Monitoring
Our MDAS Read-Only software is not for programming. This is used to read data collected from our ctemp single-use data loggers. It has all the features of the MDAS, but excludes the ability to program the devices. With IP Address access it is location independent so data loggers located anywhere can be centrally monitored and managed.
Marathon’s Data Analysis Software (MDAS) allows you to view up to 16 multiple traces at one time, enables you to transfer the information recorded in the logger to your computer, and to view, print and generate a report of the measurement data. The graphic representations include rotating 3D views, unlimited zooms, view temperature data points on the graph, view the total elapsed time or the exact time when it was recorded.
The graph and all data points (date, time and temperature) can be printed, as well as the ability to add a Note to the file for including information pertinent to that graphic trace. Users have the ability to view the numeric data within a screen window, calculate the Mean Kinetic Temperature of the recording as well as export data in a CSV format. A summary report showing the Start and Stop Time, High, Low, Median and Average temperatures as well as the Alarm information is also displayed. The data from the logger is downloaded to your PC via our proprietary RS232 serial interface cable or USB interface.
MDAS Read-Only software offers language support for English, French, German, Portuguese and Spanish. A separate installation program for Chinese and Japanese is also available on the CD-ROM with this version of the software. The software has been designed for the Microsoft operating system platforms and is compatible with Windows XP, Vista, 7, 8 and 10.
MaxiLog Cradle
DuPont Recommends The c\temp-USB-80C Single-Use Coin Cell for Dry Ice Shipments
HDMicroSystems ships liquid polyimide precursors to customers around the world. These materials – used to manufacture all portable electronic devices – must be kept cold until use. In addition, customers recognize the importance of having a “transport temperature” log to ensure material will work as expected in their manufacturing processes. Since the international transport process can take up to 5 days, the preferred coolant used by HDM is dry ice. But this puts high demands on the temperature recorder: not only must it comply with new, increasingly stringent lithium battery IATA regulations but it must continue to operate when exposed (even accidentally) to very low temperatures.
Marathon has developed a new c\temp-USB-80C Single-use Coin Cell Temperature Recorder which meets both requirements. It can be set to collect data for up to 60 days, connects to computers with standard USB mini-to-USB cables, and outputs the entire data set using a sophisticated analysis program available by download directly from the supplier. The extraordinary design works flawlessly with a lithium button battery as its power supply and survives extended periods exposed directly to dry ice (-78C). The entire recorder is compact and fits easily within all of HDM’s shipping containers (ie, small corrugated boxes to large insulated returnable shipping containers).
Marathon quickly produced the prototypes we requested and has reliably filled orders up to 1000 units. Consistency and quality of these USB-80C recorders have been critical to customer confidence in our controlled-environment international (and domestic) shipments.
–John Morgan,
Principal Engineer working in support of HDM’s Quality Assurance and Supply Chain functions.